Lieferung nur an Gewerbetreibende Gemäß §14 BGB, kein Verkauf an private Endverbraucher

GigE Trigger cabel, Hirose 6-POL 0,2m The Imaging Source GigE23/PWR/Trig

GigE Triggerkabel, 0,2m The Imaging Source GigE23/PWR/Trig
Preise auf Anfrage.
  • 303924
The Imaging Source GigE23/PWR/Trig GigE, Triggercabel, Hirose 6-POL, for PSU/Cinch23/EA... more
Product information "GigE Trigger cabel, Hirose 6-POL 0,2m The Imaging Source GigE23/PWR/Trig"

The Imaging Source GigE23/PWR/Trig

GigE, Triggercabel, Hirose 6-POL, for PSU/Cinch23/EA


The GigE trigger cable from The Imaging Source has a length of 20cm and offers connection options from Hirose to PSU / Cinch23 / EA for external triggering.

  • GigE Kabel
  • for: PSU/Cinch23/EA
  • End 1: Trigger (Trigger in), Power (Power in)
  • End 2: Hirose (Hirose)
  • For GigE 23 and 33 cameras only
  • length of 0,2 m
  • Manufactured by The Imaging Source

 

Trigger connection: 6-Pol
Related links to "GigE Trigger cabel, Hirose 6-POL 0,2m The Imaging Source GigE23/PWR/Trig"
Read, write and discuss reviews... more
Customer evaluation for "GigE Trigger cabel, Hirose 6-POL 0,2m The Imaging Source GigE23/PWR/Trig"
Write an evaluation
Evaluations will be activated after verification.

The fields marked with * are required.

Trigger input - hardware and timing

Trigger input - hardware and timing 

The trigger input of The Imaging Source USB, FireWire and GigE CCD cameras is opto-coupled. It permits positive trig- ger pulses with any amplitude between 3.3 and 12 V (24 V using a series resistance of 1 kOhm). If you intend to apply higher pulses please make sure that the current lies between the limits of 3 to 12 mA.

Trigger-Kamera

The Imaging Source USB, FireWire and GigE CCD cameras offers two different modes of operation:
Free running: The cameras generate a stream of up to 60 images/s depending on their resolution. To considerably redu- ce the amount of data, the frame rate may be reduced to 30, 15, 7.5 or 3.75 images/s. The exposures length can be set in the range of 100 μs to 30 s via software. Please note, however, that the camera's clock generator determines the actual moment of exposure. Thus, it cannot be controlled externally, but measurable using the strobe output. Therefore, this mode of operation is called "free running".
Trigger: The cameras offer a trigger input to determine the moment of exposure. The exposure begins 4.8 μs after the occurrence of a trigger pulse. The length of the exposure in the range of 100 μs to 30 s can be set via software. The dura- tion of the image readout is the reciprocal of the current frame rate. Once the image readout has finished, the camera is able to accept a new trigger pulse at any time.

Trigger-Exposure
Viewed